PERUBAHAN PERHITUNGAN EXPOSURE TIME DAN DEVELOPING TIME PADA RADIOGRAPHY TEST TERHADAP DENSITAS DAN SENSITIVITAS FILM

Pratama, Bayu Putra (2015) PERUBAHAN PERHITUNGAN EXPOSURE TIME DAN DEVELOPING TIME PADA RADIOGRAPHY TEST TERHADAP DENSITAS DAN SENSITIVITAS FILM. Diploma thesis, POLITEKNIK PERKAPALAN NEGERI SURABAYA.

Full text not available from this repository.

Abstract

Radiography test adalah sebuah pengujian tak rusak yang menggunakan sinar gamma-ray atau x-ray. pengujian ini memiliki beberapa variabel yang perlu di perhatikan dalam melakukan suatu pengujian. Terutama pemrosesan akibat dari waktu tembak, yang akan mengakibatkan adanya perbedaan sensitivitas dan densitas hasil film radiography.Sehingga di harapkan hasil penelitian ini dapat menjadi pertimbangan untuk proses pencucian. Dalam penelitian ini akan menggunakan 2 variabel perhitungan yang berbeda. yaitu perhitungan sesuai teori yang di dapat dari pedoman teknik radiografi BATAN dengan menggunakan kurva penyinaran (exposure chart),serta perhitungan yang menggunakan exposure factor yang di dapatkan dari pelatihan. Dalam pemrosesan film ini juga akan menggunakan variabel waktu yang berbeda dengan harapan mengetahui waktu yang tepat untuk melakukan proses developing. Dari penelitian ini di dapatkan hasil waktu exposeterendah dari penggunaan perhitungan exposure factoryaitu 10 detik. Sedangkan hasil waktu exposedari perhitungan sesuai teori teknik radiografi dari batan adalah 11 detik. Dari kedua metode tersebut di dapatkan hasil densitas terendah 1.8 dengan waktu pencucian 5 menit dari penggunaan perhitungan exposure factor. Sedangkan densitas tertinggi adalah 2.97 dari perhitungan menggunakan exposure chartdengan developing time7 menit.Serta sensitivitasyang di hasilkan dengan melihat wire IDpada hasil film yaitu wire ID8 pada film dengan developing time5 menit dan wire ID7 pada film dengan developing time7 menit. semua nilai hasil film dapat di nyatakan bahwa semua perhitungan relevan . Radiography test isanondestructive test that uses gamma-ray or x-ray. This test has several variables that need to be noticed in conducting a test. Processing mainly a result of firing time, which will result in the difference of sensitivityanddensity of the filmradiography results. So that the expected results of this study can be measurement for the washing process. This research will use two different calculation variables.the calculation according to the theory obtained from the guidelines BATAN radiographic techniques, as well as the calculation that uses the exposure factor in getting the training. Inthis film processing will also use a different time variables in the hope of knowing the right time to make the development process. From this research at the lowest expose get aresult from the use of exposure calculations factor is 10seconds. While the results of the calculation time expose appropriate radiographic technique theory of is11 seconds. From both these methods get results inthe lowest density of 1.8 to5minutes washing time of use exposure calculations factor. Whereas the highest density is2.97from the calculation according to the theory of a radiographic technique with a time of development 7minutes. As well as the sensitivity of which is derived by looking at the wire IDon the outcome of the film, namely wire ID8 on the film with the developed 5minutes andwire ID7 on the film with the developed 7minutes. Of all the value of the film can be in the state that all the relevant calculations for use.

Item Type: Thesis (Diploma)
Subjects: T Technology > T Technology (General)
Divisions: Jurusan Teknik Bangunan Kapal > D3 Teknik Bangunan Kapal
Depositing User: Unnamed user with email repository@ppns.ac.id
Date Deposited: 30 Aug 2018 05:19
Last Modified: 30 Aug 2018 05:19
URI: http://repository.ppns.ac.id/id/eprint/288

Actions (login required)

View Item View Item