ANALISA PENGUJIAN PERBANDINGAN BELITAN MENGGUNAKAN ALAT TRANSFORMER TURN RATIO TESTER PADA TRANSFORMATOR DENGAN DAYA 1250 KVA

Satriawan, Okta Diharto Eka (2015) ANALISA PENGUJIAN PERBANDINGAN BELITAN MENGGUNAKAN ALAT TRANSFORMER TURN RATIO TESTER PADA TRANSFORMATOR DENGAN DAYA 1250 KVA. Diploma thesis, POLITEKNIK PERKAPALAN NEGERI SURABAYA.

Full text not available from this repository.

Abstract

ABSTRAK Transformator merupakan suatu alat listrik yang dapat memindahkan dan mengubah energi listrik dari satu atau lebih rangkaian listrik ke rangkaian listrik yang lain, melalui suatu gabungan magnet dan berdasarkan prinsip induksi elektromagnet. Pada umumnya transformator terdiri atas sebuah inti, yang terbuat dari besi berlapis, dan dua buah kumparan, yaitu kumparan primer, dan kumparan sekunder. Perubahan level tegangan dari tegangan tinggi ke tegangan rendah atau sebaliknya ditentukan oleh besarnya rasio belitan transformator. Kondisi rasio belitan transformator menentukan baik-tidaknya level tegangan input dan output dari transformator tersebut. Untuk memastikan rasio belitan transformator dalam kondisi baik, maka dilakukan pengujian secara berkala. Pengujian rasio belitan transformator termasuk dalam shutdown testing/measurement yang biasanya dilakukan dua tahun sekali. Dari hasil pengujian, maka akan diketahui kondisi rasio belitan transformator yang menentukan apakah transformator tersebut masih layak digunakan atau tidak. Pada tugas akhir ini akan diuraikan pengujian rasio belitan transformator dengan daya 1250 kVA milik PT. Dwi Karya Prasetya Nusantara yang menggunakan alat Transformer Turn Ratio Tester. Penyelesaian masalah perbandingan rasio belitan transformator diselesaikan menggunakan metode analisis data, dengan hasil sebagai berikut: Pada hasil pengukuran fasa R didapatkan nilai pada tap 1 sampai tap 5 secara berurutan yaitu 0,07%, 0,23%, 0,4%, 0,15%, 0,13%. Sementara pada fasa S dari tap 1 sampai tap 5 yaitu 0,34%, 0,12%, 0,25%, 0,05%, 0,26%. Dan pada fasa T dari tap 1 sampai tap 5 yaitu 0,27%, 0,14%, 0,34%, 0,39%, 0,31%. Dari diagnosa masalah pada transformator, masih diperlukan lagi pemeriksaan lebih lanjut karena pemecahan masalahnya masih 70% dari keseluruhan masalah yang terjadi pada transformator. Kumparan transformator dapat dinyatakan dalam kondisi baik karena hasil pengukurannya tidak melebihi batas maksimum yang ditetapkan yaitu 0,5-1% (Standar ANSI/NETA ATS-2009). Kata kunci : Transformator, rasio, belitan, alat ukur, pemeliharaan, perawatan ABSTRACT The transformer is an electrical device that can move and change the electric energy from one or more electric circuit to another electric circuit, through a combination of magnet anb based on electromagnetic induction’s principle. Generally, transformer consist of a core, which is made from iron-plated, and two colis, i.e. the primary coil and secondary coil. Voltage level changes from high voltage to low voltage or otherwise determined by the magnitude of the transformer turn ratio. The condition of transformer turn ratio to determine good or not the level of input and output voltage of the transformer. To make sure the transformer turn ratio in good condition, then the test is done on regular basis. The testing of transformer turn ratio is included in shutdown testing/ measurement which is normaly done in two years. From the test result, it will be known to the condition of the transformer turn ratio that determines whether the transformer is still eligible to use or not. In this project will be elaborated the testing of transformer turn ratio with power 1250 kVA belonging to PT. Dwi Karya Prasetya Nusantara that use Transformer Turn Ratio Tester tool. The resolution of transformer turn ratio comparison problem is solved using data analysis methods, with the result as follows: On the result of the measurement of the phase R value obtained on the tap 1 to 5 respectively i.e. 0,07%, 0,23%, 0,4%, 0,15%, 0,13%. While on phase S obtain on tap 1 to 5 i.e. 0,34%, 0,12%, 0,25%, 0,05%, 0,26%. And on phase T obtain o tap 1 to 5 i.e. 0,27%, 0,14%, 0,34%, 0,39%, 0,31%. From the problems diagnoses in transformer, still need more futher examination because the solution of the problems are still 70% of the overall problems that occurs on transformer. The transformer coils can expressed in good condition because the measurement results do not exceed the maximum limit set is 0.5 – 1% (Standart ANSI/NETA ATS-2009). Keywords: Transformer, ratio, windings, instrument, maintenance, treatment

Item Type: Thesis (Diploma)
Subjects: T Technology > T Technology (General)
Divisions: Jurusan Teknik Kelistrikan Kapal > D3 Teknik Kelistrikan Kapal
Depositing User: Unnamed user with email repository@ppns.ac.id
Date Deposited: 30 Aug 2018 04:39
Last Modified: 30 Aug 2018 04:39
URI: http://repository.ppns.ac.id/id/eprint/283

Actions (login required)

View Item View Item