ANALISA PROSES REWINDING PADA TRAFO DISTRIBUSI DENGAN DAYA 1250 KVA 3 FASA

Mariono, Mochamad (2015) ANALISA PROSES REWINDING PADA TRAFO DISTRIBUSI DENGAN DAYA 1250 KVA 3 FASA. Diploma thesis, POLITEKNIK PERKAPALAN NEGERI SURABAYA.

Full text not available from this repository.

Abstract

ABSTRAK Penyaluran tenaga listrik secara terus menerus tanpa terputus adalah suatu hal yang mutlak. Maka perbaikan transformator yang benar sangat dibutuhkan. Karena pada umumnya, sebagian besar kerusakan transformator distribusi terjadi pada lilitan kumparan yang sering terjadi kerusakan transformator. Rewinding dengan mengetahui perhitungan lilitan dan pelaksanaan rewinding yang sesuai untuk mendapatkan kualitas transformator. Dua buah kumparan, yaitu kumparan primer, dan kumparan sekunder, jumlah lilitan pada kedua kumparan itu. Biasanya kumparan terbuat dari kawat tembaga yang dibelit seputar inti transformator. Metode yang dilakukan dalam proses rewinding adalah dengan cara observasi, eksperiment dan analisis data hasil pengujian tahanan isolasi, transformator apakah dapat bekerja dengan baik. Hasil pengukuran tahanan isolasi sudah sesuai standart yaitu: sekunder – body sebesar 1241,2 MΩ, hubungan Primer – body sebesar 1256,8 MΩ, hubungan sekunder – Primer didapatkan 1325,4 MΩ. Kata kunci : Lilitan, Kumparan, Tahanan Isolasi, Fasa, Transformator ABSTRACT Distribution of electricity continuously without interruption is an absolute thing. Then the correct transformer repair is needed. Because in general, most of the damage occurred in the distribution transformer coil windings. Rewinding by knowing the coil calculation and implementation of rewinding to get the quality of transformer. Two coils, the primary coil and the secondary coil is the number of both coil windings on the transformer. Usually coils made of copper wire wrapped around the core of the transformer. The method used in the process of rewinding it is with the observation, experiment and the analysis data from the result test of insulation resistance, transformer can be work well. Insulation resistance the measurement results already according to standard, that is : secondary – body connection amounted to 1241.2 MΩ, Primary – body connection amounted to 1256.8 MΩ body, secondary – Primary connection obtained 1325.4 MΩ keywords : Coil, Winding, Insulation Resistance, Phase, Transformer

Item Type: Thesis (Diploma)
Subjects: T Technology > T Technology (General)
Divisions: Jurusan Teknik Kelistrikan Kapal > D3 Teknik Kelistrikan Kapal
Depositing User: Unnamed user with email repository@ppns.ac.id
Date Deposited: 30 Aug 2018 04:22
Last Modified: 30 Aug 2018 04:22
URI: http://repository.ppns.ac.id/id/eprint/277

Actions (login required)

View Item View Item