ANALISIS KETIDAKSEIMBANGAN ARUS TERHADAP SISTEM DISTRIBUSI TEGANGAN RENDAH DI MSB (MAIN SWITCH BOARD) TRAFO PADA ME FRACT 01

Zahri, Muhammad (2015) ANALISIS KETIDAKSEIMBANGAN ARUS TERHADAP SISTEM DISTRIBUSI TEGANGAN RENDAH DI MSB (MAIN SWITCH BOARD) TRAFO PADA ME FRACT 01. Diploma thesis, POLITEKNIK PERKAPALAN NEGERI SURABAYA.

Full text not available from this repository.

Abstract

ABSTRAK Sistem Distribusi merupakan bagian dari sistem tenaga listrik yang berguna untuk menyalurkan tenaga listrik dari sumber daya listrik PLN maupun Power Plant diturunkan menjadi tegangan menengah kemudian diturunkan lagi ke tegangan rendah atau sampai ke konsumen. Sistem distribusi adalah suplai yang paling dekat dengan beban, oleh karena itu banyak sekali permasalahannya. Permasalahan yang sering terjadi adalah ketidakseimbangan arus. Penyebab terjadinya ketidakseimbangan tersebut adalah pada beban antara tiap-tiap fasa R, S dan T di sistem distribusi tegangan rendah. Akibatnya dapat melebihi standar NEMA MG-1-1998. Hal tersebut dapat menimbulkan arus netral pada trafo. Arus yang mengalir di netral trafo ini menyebabkan terjadinya losses (rugi-rugi). Setelah dianalisa, ketidakseimbangan arus yang terjadi sebesar 10,267% dan arus netral yang terjadi pada penghantar netral trafo sebesar 79 ampere. Untuk memperbaiki ketidakseimbangan dengan cara menyeimbangkan beban dan memakai kawat penghantar netral yang sama dengan phase-nya. Kata kunci : Sistem Distribusi, Ketidakseimbangan Arus, Arus Netral, Losses (Rugi-rugi) ABSTRACT The distribution system is part of a power system that is useful to transfer power from the source of PLN power and power plant was lowered to medium voltage and then lowered again to a low voltage or to the consumer. The distribution is the suply of the closest to the load, therefore a lot of problems. Experiences to what often happens is unbalance current. The cause of the imbalance is on the load between each phase R, S and T in low voltage distribution systems. The result can exceed NEMA standards MG-1-1998. This can cause the neutral current transformer. Current flowing in the transformer neutral is causing losses. Once analyzed, unbalance current that occurs at 10.267% and neutral currents that occur in the neutral conductor transformer at 79 amperes. To correct imbalances by balancing the load and wear neutral wires together with its phase. Keywords : Distribution System, Unbalance Current, Neutral Current, Losses

Item Type: Thesis (Diploma)
Subjects: T Technology > T Technology (General)
Divisions: Jurusan Teknik Kelistrikan Kapal > D3 Teknik Kelistrikan Kapal
Depositing User: Unnamed user with email repository@ppns.ac.id
Date Deposited: 30 Aug 2018 02:47
Last Modified: 30 Aug 2018 02:47
URI: http://repository.ppns.ac.id/id/eprint/259

Actions (login required)

View Item View Item