PEMETAAN POLA DISPERSI EMISI SO 2 DAN PENENTUAN ASSEMBLY POINT SERTA EVACUATION ROUTE MAP (Studi Kasus : PT. Petro Jordan Abadi)

Nining, Wahyuni (2015) PEMETAAN POLA DISPERSI EMISI SO 2 DAN PENENTUAN ASSEMBLY POINT SERTA EVACUATION ROUTE MAP (Studi Kasus : PT. Petro Jordan Abadi). Diploma thesis, POLITEKNIK PERKAPALAN NEGERI SURABAYA.

Full text not available from this repository.

Abstract

ABSTRAK PT. Petro Jordan Abadi (PT. PJA) merupakan salah satu industri yang memproduksi asam fosfat dan asam sulfat yang berada di kota Gresik. Industri ini menghasilkan emisi berupa gas sulfur dioksida (SO2 ) yang diperoleh dari unit Sulphuric Acid Plant (SA Plant). Emisi ini dikeluarkan melalui cerobong asap (stack) D-1303 yang dapat mencemari lingkungan. Tersedianya informasi awal tentang kemungkinan tercemarnya suatu daerah didekat kawasan industri pada waktu tertentu akan banyak membantu dalam antisipasi terhadap akibatnya. Untuk menentukan atau mengetahui pola dispersi yang dikeluarkan dari cerobong dapat menggunakan beberapa model, sehingga pada penelitian ini bertujuan untuk memodelkan pola dispersi emisi SO2 yang dikeluarkan oleh cerobong asap PT. Petro Jordan Abadi menggunakan persamaan Gaussian Plume Model, menentukan letak assembly point dan menentukan rencana evacuation route map bagi pekerja yang ada di plant. Penelitian ini menggunakan metode Gaussian Plume Model untuk mengetahui sebaran konsentrasi polutan pada jarak tertentu dan Caraway untuk menentukan konsentrasi maksimum pada suatu area. Hasil penelitian menunjukkan bahwa konsentrasi maksimum pada arah downwind centerline rata-rata dari bulan Mei-Agustus ialah sebesar 41414.09 µg/m 3 . Adapun mengenai jumlah assembly point yang ditentukan ada 4 titik lokasi yang dapat menampung seluruh pekerja di PT. Petro Jordan Abadi yang berjumlah 243 pekerja dan disertai peta rute evakuasi menuju assembly point. Kata kunci: Assembly Point, Dispersi emisi SO 2 , Evacuation route map, Persamaan Gaussian Plume Model. ABSTRACT PT. Petro Jordan Abadi (PT. PJA) is one of industry that produce asam fosfat dan asam sulfat in gresik city. This industry produces gaseous emissions of sulfur dioxide (SO 2 ) obtained from Sulphuric Acid Plant (SA Plant). These emissions released through the chimney (stack) D-1303 which can pollute the environment. Initial information about the possibility of contamination of an area near industrial area at a particular time will help a lot in anticipation of the impact. To determine or know the dispersion pattern emitted from the chimney can use several models, so in this study aims to model the dispersion pattern of SO 2 emissions released by the chimney PT. Petro Jordan Abadi using Gaussian Plume Model equations, determining the location of assembly points and determine the evacuation route map for the workers in the plant. This study uses a Gaussian Plume Model to determine the distribution of pollutant concentrations at a certain distance and Caraway to determine the maximum concentration in an area. The results showed that the maximum concentration on the average downwind direction centerline of the month from May to August was at 41414.09 μg/m 3 . As to the number of assembly points specified there are 4 point location that can accommodate all 243 workers at PT. Petro Jordan Abadi with the evacuation route map towards the assembly point. Keywords: Assembly Point, Dispersion SO 2 emissions, Evacuation route map, Equations Gaussian Plume Model.

Item Type: Thesis (Diploma)
Subjects: T Technology > T Technology (General)
Divisions: ?? tkdkk ??
Depositing User: Unnamed user with email repository@ppns.ac.id
Date Deposited: 27 Aug 2018 06:26
Last Modified: 27 Aug 2018 06:26
URI: http://repository.ppns.ac.id/id/eprint/155

Actions (login required)

View Item View Item