PENILAIAN RISIKO MENGGUNAKAN METODE SWEHI PADA UNIT GAS STATION PT. INDONESIA POWER UP PERAK-GRATI

Firmansyah, Fendi Ilham (2017) PENILAIAN RISIKO MENGGUNAKAN METODE SWEHI PADA UNIT GAS STATION PT. INDONESIA POWER UP PERAK-GRATI. Diploma thesis, POLITEKNIK PERKAPALAN NEGERI SURABAYA.

Full text not available from this repository.

Abstract

ABSTRAK Setiap industri yang memiliki kegiatan produksi menggunakan bahan kimia berbahaya memiliki potensi bahaya kebakaran, ledakan serta terlepasnya bahan kimia beracun. PT Indonesia Power UP Perak Grati merupakan perusahaan pembangkit listrik yang memanfaatkan Gas Alam sebagai bahan bakar utama, sehingga memiliki berbagai macam potensi bahaya. Pada akhir Desember 2016, sumber baru telah ditambahkan untuk menambah pasokan Gas Alam sebagai bahan bakar gas turbin yang berdampak pada perubahan kondisi operasi. Unit pertama yang terkena dampak akibat penambahan ini adalah Gas Station. Sebagai tindakan preventif perlu diadakan identifikasi bahaya dan penilaian risiko lagi untuk mengetahui serta menangani risiko yang ada pada unit Gas Station. Safety Weighted Hazard Index (SWeHI) merupakan metode index bahaya secara kuantitatif. Metode ini mampu mengidentifikasi index bahaya kebakaran, ledakan, dan terlepasnya bahan berbahaya serta keefektifan penanganan bahaya yang ada. Dari perhitungannya SWeHI mempertimbangkan derajat bahaya serta dibandingkan dengan penanganan bahayanya. Derajat bahaya diperoleh dengan mempertimbangkan nilai bahaya kebakaran dan ledakan (B1) dengan bahaya terlepasnya bahan kimia (B2). Hasil dari penelitian ini adalah besarnya bahaya dari tiap komponen dari gas station adalah Highly Hazardous untuk Inlet Scrubber dan Condensate Tank, serta Hazardous untuk Filter Separator. Bahaya yang ada pada tiap komponen adalah bahaya kebakaran dan ledakan. Risk Ranking menggunakan metode SWeHI pada tiap komponen adalah Less Hazardous untuk Inlet Scrubber dan Condensate Tank serta Non Hazardous untuk Filter Separator. Setelah diberikan rekomendasi untuk penambahan frekuensi pelatihan tiap tahunnya, penambahan sistem komputasi untuk pengontrolan proses, pemasangan pendeteksi bahaya seperti pendeteksi bahan kimia beracun, dan penambahan interlock untuk Condensate Tank didapatkan Non Hazardous untuk semua komponen pada unit Gas Station. Kata kunci : index bahaya, penilaian risiko, risiko kuantitatif, kebakaran, ledakan ABSTRACT Every industry which has production activities, uses hazardous chemicals that have a potential fire hazard, explosion and release of toxic chemicals. PT Indonesia Power UP Perak Grati is a power generation company that utilizes Natural Gas as the main fuel, so it has various potential hazards. At the end of December 2016, new sources have been added to supply the Natural Gas as turbine gas fuel which impacts on changing operating conditions. The first unit affected by this addition is the Gas Station. As a preventive measurement, it is necessary to identify hazard and risk again to know and handle the risks that exist in the Gas Station unit. Safety Weighted Hazard Index (SWeHI) is a quantitative method of hazard index. This method is capable to identify the index of fire hazard, explosion, and release of hazardous materials and the effectiveness of handling the existing hazards. From its calculations, SWeHI considers the degree of hazard and also compares to the handling of the hazards. The level of the danger is obtained by considering the value of fire and explosion hazard (B1) with the danger of chemical release (B2). The results of this study shows that the magnitude of the hazards of each component of the Gas Station are Highly Hazardous for Inlet Scrubber and Condensate Tank, and Hazardous for Filter Separator. The dangers present in each component are fire and explosion hazards. Risk Ranking using SWeHI method on each component is Less Hazardous for Inlet Scrubber and Condensate Tank and Non Hazardous for Filter Separator. After recommendation for additional training frequency every year, addition of computation system for process control, hazard detection installation such as toxic chemical detection, and addition of interlock for Condensate Tank obtained Non Hazardous for all components in Gas Station unit. Keywords: hazard index, risk assessment, quantitative risk, fire, explosion

Item Type: Thesis (Diploma)
Subjects: T Technology > T Technology (General)
Divisions: ?? tkdkk ??
Depositing User: Unnamed user with email repository@ppns.ac.id
Date Deposited: 21 Sep 2018 05:47
Last Modified: 21 Sep 2018 05:47
URI: http://repository.ppns.ac.id/id/eprint/1128

Actions (login required)

View Item View Item