ANALISA GANGGUAN DAN SETTING SISTEM PROTEKSI MOTOR POMPA AIR UMPAN BOILER MP 1101 MENGGUNAKAN EOCR-I3BZ DI PEMELIHARAAN III PT. PETROKIMIA GRESIK

Matofani, Aditya (2017) ANALISA GANGGUAN DAN SETTING SISTEM PROTEKSI MOTOR POMPA AIR UMPAN BOILER MP 1101 MENGGUNAKAN EOCR-I3BZ DI PEMELIHARAAN III PT. PETROKIMIA GRESIK. Diploma thesis, POLITEKNIK PERKAPALAN NEGERI SURABAYA.

Full text not available from this repository.

Abstract

ABSTRAK Motor pompa MP 1101 ini sebagai motor air umpan boiler yang mengalirkan air yang telah selesai melalui proses demineralisasi menuju ke boiler di bagian pemeliharaan III PT. Petrokimia Gresik. Motor pompa ini dilengkapi dengan proteksi EOCR (Electronic Over Current Relay), yaitu sebuah peralatan yang berfungsi untuk mengamankan motor ketika terjadi gangguan arus lebih. Alat pengaman ini dapat bekerja untuk memutus aliran listrik menuju ke motor pompa MP 1101 apabila motor terjadi gangguan over current ataupun gangguan yang termasuk di dalam karakteristik EOCR. Dari analisis yang dilakukan dapat ditarik beberapa kesimpulan bahwa karakteristik yang dimiliki sistem proteksi EOCR lebih banyak dari pada Over Current, proteksi EOCR sebanyak 9 dan 3 yang terdapat pada Over Current. Gangguan yang sering terjadi pada motor lebih banyak disebabkan kondisi panas pada bearing dan membutuhkan over houl setiap 1 tahun sekali. Dalam perhitungan arus starting motor diperoleh 185,3 A atau 6 kali arus nominal motor, sedangkan dalam pengaturan yang terseting oleh teknisi 8 kali arus nominal. Pengaturan untuk arus starting ini tidak boleh terlampau dari set poin yang ditentukan, hal ini dapat mengakibatkan motor terbakar. Gangguan selain dari sistem kelistrikan yaitu panas yang sering terjadi pada bearing motor, hal ini dapat diminimalisir dengan pemberian greasing/pelumas secara terjadwal agar kinerja motor dapat berjalan dengan baik dan tidak mendapatkan suhu yang berlebihan. Kata Kunci: EOCR, Motor Pompa MP 1101, Over Current, Proteksi ABSTRACT Motor pump MP 1101 used as a boiler feed water motor to drain water that has been completed through the demineralization process to the boiler at the third maintenance PT. Petrokimia Gresik. This pump motor is equipped with EOCR (Electronic Over Current Relay) protection, which is a device that serves to secure the motor when there is over current interruption. This safety device use to break the flow of electricity to the motor pump MP 1101 if the motor over-current or interference occurs in the characteristics of EOCR. From the analysis can be drawn some conclusions that the characteristics of EOCR protection system more than the Over Current Relay, EOCR has 9 protection and Over Current Relay has 3 protection. Disturbances that often occur in the motor more due to heat conditions in the bearing and require over houl every 1 year. In the calculation of motor starting current obtained 185.3 A or 6 times the nominal current of the motor, while in the settings, technicians use 8 times of the nominal current. The setting for this starting current should not be too far from the specified set point, this may can burn the motor. The other Disturbance expect from the electrical system is the heat that often occurs in the bearing motors, this can be minimized by give of greasing / lubricants on right scheduled for keep motor performance run well and do not get excessive temperature. Keywords: EOCR, MP 1101 Motor Pump, Over Current, Protection

Item Type: Thesis (Diploma)
Subjects: T Technology > T Technology (General)
Divisions: Jurusan Teknik Kelistrikan Kapal > D3 Teknik Kelistrikan Kapal
Depositing User: Unnamed user with email repository@ppns.ac.id
Date Deposited: 20 Sep 2018 05:23
Last Modified: 20 Sep 2018 05:23
URI: http://repository.ppns.ac.id/id/eprint/1020

Actions (login required)

View Item View Item