Simulasi Prototipe Monitoring Suhu Air Cooling Tower dan Otomatisasi Exhaust Fan Pada Cooling Tower Berbasis Mikrokontroler

Prasetio, Tri Yuda (2017) Simulasi Prototipe Monitoring Suhu Air Cooling Tower dan Otomatisasi Exhaust Fan Pada Cooling Tower Berbasis Mikrokontroler. Diploma thesis, POLITEKNIK PERKAPALAN NEGERI SURABAYA.

Full text not available from this repository.

Abstract

ABSTRAK Cooling Tower pada sebuah industri digunakan sebagai pendingin uap air sisa dari condesat tank dari generator sebagai keperluan water treatment. Cooling Tower yang dibahas dilenkapi dengan 4 motor fan yang berfungsi sebagai mengeluarkan suhu panas dalam cooling tower ke udara agar sesuai dengan ketentuan suhu yang di perlukan untuk dipompa dan di alirkan pada water treatmen di demin tank pada unit deminetralis. Untuk memantau cooling tower dapat dilihat pada ruang CCR (Central Control Room) dan untuk pelaksana atau yang mengoperasikan Cooling Tower ada di ruang khusus operator. Bila dalam keadaan suhu melebihi yang ditentukan maka pihak di CCR harus menghubungi pihak pelaksana untuk mengakifkan kipas/fan tambahan guna dapat mendinginkan air agar sesuai dengan ketentuan. Melihat ada yang kurang efektif dalam pengoperasian Cooling Tower penulis memberikan sebuah inovasi yaitu “SIMULASI PROTOTIPE MONITORING dan OTOMASISASI EXHAUST FAN PADA COOLING TOWER BERBASIS MIKROKONTROLER”. Sistem dari monitoring dan otomatisasi berbasis mikrokrontroler ini merupakan memantau kondisi suhu air yang masuk dan keluar pada Cooling Tower dan mengaktifakn secara otomatis kipas/fan tambahan yang ada dengan menggunakan sensor suhu dan mengolah dengan Mikrokontroler Arduino. Diharapkan dengan adanya penelitian ini dapat mempermudah dalam memantau suhu Cooling Tower serta dapat pula membantu dalam pengoperasianya. Pengujian yang dilakukan diperoleh beberapa hasil dari pengujian tersebut. Sensor yang bekerja setelah dibandingkan menghasilkan selisih pembacaan dengan thermometer sebesar 0,30 °Celcius dengan perhitungan presentase error mencapai 0,0037%. Setpoint penanda apabila suhu tinggi adalah 45,5 °Celcius dengan langsung menyalakan exhaust fan tambahan pada cooling tower. Sementara setpoint untuk mematikan kembali adalah pada suhu dibawah 42,2°Celcius. Kata Kunci: Cooling Tower, Mikrokontroler Arduino, Monitoring, Otomatisasi ABSTRACK Cooling Tower in an industry is used as residual water vapor refrigerant from condensate tanks from generator as water treatment requirement. The cooling towers discussed are equipped with 4 fan motors that function as a hot temperature in the cooling tower to the air in order to comply with the temperature requirements needed to be pumped and streamed to the water treatment in the demin tank on the demineral unit. To monitor the cooling tower can be seen in the CCR (Central Control Room) room and for executing or operating the Cooling Tower is in the operator's special room. If the temperature exceeds that specified, the party at the CCR must contact the implementing party to enable additional fan in order to cool the water to comply with the provisions. Seeing that there is less effective in the operation of Cooling Tower the author gives an innovation that is "SIMULATION PROTOTYPE MONITORING WATER TEMPERATURE COOLING TOWER and EXHAUST FAN AUTOMATION BASED MICROCONTROLLER". The system of monitoring and automation based on this microcontroller is monitoring the condition of incoming and outgoing water temperature at Cooling Tower and automatically activate additional fan / fan by using temperature sensor and processing with arduino microcontroller. It is expected that with this research can facilitate in monitoring Cooling Tower temperature and can also assist in the operation. Tests conducted obtained some results from the test. Sensors that work after comparing the resulting difference with a thermometer reading of 0.30 ° Celcius with the calculation percentage of error reached 0.0037%. Setpoint marker when the high temperature is 45.5 ° Celsius by directly turning on the exhaust fan on the cooling tower. While the setpoint to turn back is at a temperature below 42.2 ° Celsius. Keywords: Cooling Tower, Arduino Microcontroller, Monitoring, Automation.

Item Type: Thesis (Diploma)
Subjects: T Technology > T Technology (General)
Divisions: Jurusan Teknik Kelistrikan Kapal > D3 Teknik Kelistrikan Kapal
Depositing User: Unnamed user with email repository@ppns.ac.id
Date Deposited: 20 Sep 2018 04:44
Last Modified: 20 Sep 2018 04:44
URI: http://repository.ppns.ac.id/id/eprint/1009

Actions (login required)

View Item View Item