Frediansha, Ricco Putra (2017) STUDI PERANCANGAN SISTEM SUPLAI DAYA LISTRIK DARURAT DAN ATS ( AUTOMATIC TRANSFER SWITCH ) PADA MOTOR POMPA MP 9306 DI PABRIK III PT PETROKIMIA GRESIK. Diploma thesis, POLITEKNIK PERKAPALAN NEGERI SURABAYA.
Full text not available from this repository.Abstract
ABSTRAK Keandalan suplai daya merupakan hal penting yang harus diperhatikan dalam melakukan perancangan instalasi suatu tempat. Gangguan pada sistem kelistrikan di industri dapat mengakibatkan ketidakseimbangan proses produksi, terutama pada mesin mesin vital. Motor pompa MP 9306 merupakan salah satu mesin vital di Pabrik IIIA PT Petrokimia Gresik, berfungsi sebagai penyuplai air untuk keperluan operasional pabrik III. Sumber listrik pada Pabrik III A PT Petrokimia Gresik memanfaatkan dua buah generator yang telah disinkronkan yakni TG 65 dan TG 66. Terdapat beberapa pembangkit listrik alternatif yang bisa digunakan sebagai suplai listrik cadangan yakni Utilitas Batu Bara (UBB). Selama ini apabila terdapat kendala pada sumber listrik utama, maka dilakukan penyewaan generator set (genset) sebagai sumber listrik cadangan. Tingginya biaya sewa genset membuat biaya produksi semakin tinggi. Sehingga perencanaan sistem suplai daya listrik darurat dengan memanfaatkan pembangkit alternatif, serta perencanaan Automatic Transfer Switch (ATS) untuk pemindahan kedua suplai bisa menjadi jalan alternatif untuk menekan biaya produksi dan kontinuitas produksi. Metode perencanaan yang digunakan yaitu dengan mempertimbangkan jarak suplai pembangkit alternatif dengan beban motor. Adanya susut tegangan yang tinggi serta kemampuan penghantar yang terbatas menyebabkan pendistribusian listrik menjadi terganggu. Perencanaan panel ATS dibuktikan dan disimulasikan dengan software EKTS. Hasil dari perencanaan ini diharapkan dapat memberikan kontinuitas suplai motor dan menghemat pengeluaran perusahaan sebanyak 66,7% atau sekitar Rp. 508.806.000. Kata Kunci : Keandalan, darurat , Automatic Transfer Switch(ATS). ABSTRACT Reliability of power supply is an important thing that must be considered in the design of the installation of a place. Disturbance to electrical systems in industry can lead to imbalance in production processes, especially on vital machine engines. MP 9306 pump motor is one of the vital machines in III A factory PT Petrokimia Gresik , serves as a water supply for the operational purposes of factory III. The power source at the III A Plant PT Petrokimia Gresik utilizes two synchronized generators, namely TG 65 and TG 66. There are several alternative power plants that can be used as a backup power supply, namely Utility Batu Bara (UBB). So far, if there are constraints on the main power source, then the rental generator set (generator) as a backup power source. The high cost of generating rental generates higher production costs. So planning the emergency power supply system by utilizing alternative generators, as well as the planning of Automatic Transfer Switch (ATS) for the transfer of both supplies can be an alternative way to reduce production costs and production continuity. The planning method used is to consider the distance of alternative power supply with motor load. The presence of high voltage shrinkage and limited delivery capability cause the distribution of electricity to be disrupted. ATS panel planning is proven and simulated with EKTS software. The results of this plan are expected to provide continuity of motor supply and save company expenses of 66,7% for five years Keyword : Reliability , emergency, Automatic Transfer Switch (ATS)
Item Type: | Thesis (Diploma) |
---|---|
Subjects: | T Technology > T Technology (General) |
Divisions: | Jurusan Teknik Kelistrikan Kapal > D3 Teknik Kelistrikan Kapal |
Depositing User: | Unnamed user with email repository@ppns.ac.id |
Date Deposited: | 20 Sep 2018 04:37 |
Last Modified: | 20 Sep 2018 04:37 |
URI: | http://repository.ppns.ac.id/id/eprint/1006 |
Actions (login required)
View Item |